Water Damage Category And Class
The following information will help you to understand the many technical terms and definitions associated with water damage.Category 1 – This first category of water is Sanitary water and it poses no major health risks to you or your family. You can drink it, wash with it, or (if it is steaming), you can inhale it safely. Most of the water that comes into your home will be Category 1 until it leaves its source, either a supply line, an appliance, or melting snow or rain. Category 1 water is also called “Clear Water.”
Once clear water leaves its source, however, it can quickly become contaminated and deteriorate to Category 2 or 3. Water with a foul odor is a good indicator that it has been mixed with soil or other pollutants
Category 2 – This water is definitely contaminated and is unsafe for either contact or consumption by you or your family. Category 2, or Gray Water, is typically “overflow” water from an appliance, toilet, aquarium or waterbed.Like clear water, gray water will also deteriorate and become foul smelling. This process will take less time to become toxic, and should not go unattended for long.
Category 3 – This category of water is grossly contaminated and may be highly toxic to you and your family. Called Black Water, it may contain raw sewage, pesticides, heavy metals or toxic organic substances.
Unlike the first two categories, Black Water will have a foul smell and likely contain pathogenic, toxigenic, or other harmful agents.
Class of Water is determined by the probable rate of evaporation based on the type of materials affected, or wet, in the room or space that was flooded. Determining the Class of Water in an important first step, and will determine the amount and type of equipment utilized to dry-down the structure.Class 1 – Low end of the scale. Minor extraction required and few if any materials affected. Quickest drying time.
Class 2 – Middle of the scale. Entire space, or room, flooded with wicking less than 2 feet up walls.
Class 3 – High end of the scale. Usually designates flooding from above. Ceiling and walls saturated above the 2 foot level. Heavy extraction required.
Class 4 – Unique or Specialty drying situations.
- An opening through which water can enter.
- A physical force to move the water.
- Gravity
- Air currents
- Capillary suction
- Surface tension
- Kinetic energy (momentum)
- Air pressure
- Hydrostatic pressure
Air Currents—Rain occurring in the absence of wind (or on the leeward side of a building) strikes only the horizontal and sloping surfaces of a building, while the vertical surfaces stay dry. Rain driven by wind, though, is carried at an angle by the air currents and strikes the walls as well. Wind patterns create swirling currents at the tops and corners of buildings, increasing the wetted area at these locations (Figure 2). The tops and edges of a building may be subjected to 20 to 30 times as much rain wetting as the center portion of a facade. This means that parapet walls are at a higher risk of winddriven rain penetration than any other element of a building.
Figure 1: Forces causing water penetration through building enclosures.
Capillary Suction—Small capillary passages (less than 1/8") in and between exterior building materials can create a suction force which draws in water. The smaller the passage, the greater the force and the higher the capillary potential. A material with fine capillary passages will attract and retain more water than one with larger capillary passages. Surface Tension—Water clings to a surface by surface tension. Water that is flowing down the face of a vertical surface will turn and follow the profile of the surface flowing horizontal
Drytech Restoration Services LLC. Spring City Pa. 19475
Figure 2: Wind increments wetting at building top and corners.
ly onto soffits and into cracks, joints and openings.
Kinetic Energy (Momentum)— The momentum of blowing rain will carry it directly through open windows, doors and joints. If the openings are small, or if the trajectory of the rain is such that it cannot enter directly, water can splash into openings—rain drops can splash from a sill through an open window or attic vent or splash into a joint.
Air Pressure—In addition to the force of wind driving rain against a surface and blowing it into openings, wind also creates air pressure differentials across the building envelope. The total air pressure difference between the outside and the inside of a wall is produced by the combined effects of wind, stack effect, and mechanical ventilation. Wind pressure has the most effect on rain penetration. The exact pressure differential at any given point on a wall or roof will vary depending on the location with respect to the wind direction and the shape of the building. Pressure differences on a wall can force water through even microscopic openings in a building envelope through a sort of pumping action, and wind pressure can even drive water uphill.
Hydrostatic Pressure—Both standing water and ground water can exert hydrostatic pressure against a building envelope.
Ground water in the soil exerts hydrostatic pressure against a basement waterproofing membrane. The deeper the structure, the greater the pressure exerted. Ponded water exerts gravitational pressure on a roof membrane, but also exerts hydrostatic pressure on the vertical flashings and joints. Continuous hydrostatic pressure places stringent requirements on waterproofing membranes and will cause failure at even small flaws or discontinuities.
PREVENTING WATER PROBLEMS
It is not possible to eliminate rain, snow, and ground water or the forces that move them, and it is impossible or impractical to eliminate all of the intentional and inadvertent openings and penetrations which occur in a building enclosure. It is possible, though, to mitigate the factors which contribute to water penetration by applying three basic moisture protection strategies.
- Limit water penetration into a building or building enclosure with: Barriers such as membranes and joint sealants. Diversions such as sloping surfaces and gutters. Screens such as projections and baffles.
- Prevent water accumulation by providing: Drainage. Drying/evaporation. Ventilation.
- Neutralize the physical forces that transport water with: Capillary breaks. Drips. Protected openings. Rain screens.
It is difficult to eliminate water penetration but relatively simple to limit it. Continuous roofing and waterproofing membranes form barriers to prevent water penetration through cracks and openings and into porous surfaces. The effectiveness of these barriers, however, depends on membrane continuity, the integrity of seams and joints, and properly detailed flashing at perimeters and penetrations. Elastomeric sealants prevent water penetration through large joints, but installation must be near perfect to form a complete barrier.
Water penetration can be limited by diverting the flow of water as it crosses the building enclosure. Sloped surfaces, for example, are effective in draining water quickly from a roof, coping, or sill so that it has less opportunity to penetrate through cracks or imperfections. Considering the inaccuracy of the construction process and the anticipated tolerances in erecting and assembling building components, most flat surfaces actually slope in one direction or another and the unintended slope can easily be in a direction which collects rather than sheds water.
Water penetration can also be limited by reducing the amount of water that strikes building surfaces and joints. Overhangs and projections can protect walls and openings from rain; louvers can shield an attic vent; baffles or batten strips can block joints; and gutters with downspouts can direct water away from foundation walls.
30 • Interface October 2000
Figure 3: Shields and labyrinths keep water out of joints.
Preventing Water Accumulation Water that penetrates a building enclosure may not necessarily cause damage if it can be drained or dried quickly. Flashing and weep holes are used in many different kinds of building systems to collect and drain water that has penetrated the exterior surface. Porous materials can be protected from excessive surface absorption with coatings or water repellent treatments, and drying can be expedited by allowing air circulation behind the cladding.
Neutralizing Forces
To resist water penetration caused by gravity flow, particular attention must be paid to horizontal surfaces. Wall caps or copings should be sloped to shed water, and the joints sealed with a highperformance sealant. Roofs should slope to drains, scuppers, or overhangs. Window sills and other projections should be sloped to the outside so that water will run off. A minimum 15degree slope is generally recommended for sills.
To prevent rain penetration caused by the kinetic energy or momentum of the rain, roof overhangs and projections such as balconies and porches provide much the same protection as an umbrella, intercepting the rain drops before they strike the wall surface. Similarly, a shield in front of an opening will stop the rain. A shield can be incorporated in the joints between components of the cladding such as a batten strip on vertical wood siding, or the joint itself can be shaped or baffled to avoid a straightthrough opening (Figure 3). It is not necessary for these devices to be sealed tightly to prevent the momentum of the rain from carrying it through the opening, so small imperfections are of little consequence.
To prevent the penetration of water caused by surface tension, the surface profile should be designed to break the surface tension and force water to drip off. Since water cannot flow upward without some force being applied, a sharp change in direction to another vertical surface will cause the water to collect until its weight is sufficient that gravity overcomes the surface tension, and the water drips downward. Figure 4 shows several examples of drip profiles or "drips" that can be incorporated in masonry, precast, EIFS, and stucco systems.
Capillary suction can be eliminated by interrupting the passages with a sheet material such as metal flashing or a waterproofing membrane. Capillary suction can also be eliminated by introducing an air gap into the mois
and gravel beds are effective capillary barriers commonly used in drainage type wall systems such as masonry cavity walls, under floor slabs, and adjacent to basement walls. Air gaps in vertical walls or joints can also serve as drainage channels to direct penetrated water back to the outside.
To prevent the penetration of rain blown against a building by air currents, openings in the enclosure must be shielded in a manner similar to that discussed under kinetic energy forces.
Roof overhangs protect the tops of walls, balcony and porch
Figure 4: Drips break surface tension.
October 2000 Interface • 31projections shield door openings, and awningtype windows allow natural ventilation while shielding the opening from blowing rain. Similarly, a shield incorporated in the joints between components of the cladding in the form of baffles or splines will
Figure 5: Capillary breaks prevent suction.
Figure 6: Hydrostatic pressure relief.
a wall stops rain penetration caused by air pressure. Pressure
BARRIERS, DRAINS, AND RAIN SCREENS
The design concepts which incorporate
one or more of these three basic moisture
protection strategies are barrier systems,
drainage systems, and rain screen systems.
Barrier systems attempt to limit the number of
openings in a building envelope. Drainage
systems limit the amount of water that can
accumulate by controlling its flow. Rain
screens neutralize some of the primary forces
which move water through the enclosure.
Barrier systems are also sometimes referred to as "face seal" or "prime seal" methods of moisture protection. Barrier systems are commonly used in roofing, belowgrade waterproofing, EIFS, architectural precast cladding, and metal building systems (Figure 7). Barrier systems rely exclusively on an air and water seal at the exterior weathering surface. All exterior joints and openings must be perfectly sealed or water will enter and be trapped inside the wall. To expect such perfection is unrealistic because a building that relies on joint sealants and surface treatments as its first and only line of defense will eventually leak.
32 • Interface October 2000
Figure 8: Drainage type systems.
Figure 7: Rain barrier type systems.
lation. Exterior seals are difficult to achieve and maintain because of expansion and contraction and longterm exposure to ultra violet radiation. Interstitial condensation from interior moisture sources can also be a problem since barrier systems do not incorporate any method of venting or drainage. Barrier systems are the least expensive method of providing initial weather resistance, but they require frequent maintenance of sealant joints to assure satisfactory performance.
Drainage Systems
Drainage systems incorporate a cavity or membrane behind the exterior weathering surface to collect moisture which may penetrate the outer plane. The cavity is then drained of penetrated water by flashing and/or weeps (Figure 8). Drainage systems can be used in masonry, precast concrete, stucco, metal roofs and metal windows. Drainage systems provide redundant protection where the exterior skin stops most of the incident rain but does not have to function as a perfect barrier. The internal collection and drainage system provides a second line of defense and prevents water from penetrating to the interior. Drainage systems are generally more expensive than barrier systems, but when properly designed and constructed, they require less maintenance, have a longer expected service life, and provide a higher level of protection against water penetration.
Drainage systems are more forgiving than barrier systems but can still experience water penetration problems if the flashing and weeps are not adequately designed and installed.
Rain Screen Systems
Rain screen systems create a pressureequalized cavity behind the cladding and must include a structurally supported air barrier, a sealed and compartmented air chamber, adequate drains, and external vents. Wind pressure is transmitted to the cavity through drain and vent holes, while an air barrier and sealed compartments confine the cavity pressure and prevent air from moving to the building interior or around corners (Figure 9).
Figure 9: Rain screen system concept.
October 2000 Interface • 35As a rule of thumb, intentional openings in the outer wall should be ten times the area of the unintentional openings in the air barrier. The force producing rain penetration and the quantity of water penetrating the exterior surface is thus reduced to about one tenth of what it would have been. The air chamber may also serve as a drainage cavity for collecting penetrated water and directing it back to the outside.
Rain screens are high performance wall systems. They provide multiple layers of protection by limiting water penetration, collecting and draining penetrated water, and moving the primary air seal from the weathering surface of the wall to a protected location within the wall. Rain screen systems are more expensive than barrier and drainage wall systems, but they also have the lowest maintenance and the highest safety factor in protecting against water infiltration.
Combining Protective Strategies
In reality, many enclosure systems use a combination of methods to resist water penetration. A building might consist of barrier membrane waterproofing below grade with a drainage medium provided as a capillary break to hydrostatic pressure; a sloping roof to shed snow and rain; a pressureequalized aluminum curtain wall system; and a masonry cavity wall with flashing and weeps for drainage. A combination of protective strategies can be selected based on the type of building and its occupancy requirements, the severity of macroand microenvironmental exposure, and appropriateness for the type of building system under consideration. ■
**This article is based on material from Ms. Beall’s book Thermal and Moisture Protection Manual (McGrawHill, 1999), reprinted here with permission.
http://www.restore-911.com Spring City ,Collegeville,Royersford,Pottstown,King of Prussia